Diese Seite ist noch nicht fertig.
So sollen wir unsere Verbindungen beschalten oder ???
X.21 DTE - Dieses Kabel geht zum CISCO zum X.21 Interface.
Description | X.21 Kabel vom Cisco zum FME |
15 Pin Kabel- Belegung |
Signal | am anderen Ende ? | |||
Single | -- | 1 = Ground | Shield GND | Single | 1 | Shield GND | |
Twisted pair no. 3 | ===> ===> |
2 9 |
Transmit+ Transmit-- |
Twisted pair no. 3 |
===> ===> |
4 11 |
Receive+ Receive-- |
Twisted pair no. 2 | ===> ===> |
3 10 |
Control+ Control-- |
Twisted pair no. 2 |
===> ===> |
5 12 |
Indication+ Indication-- |
Twisted pair no. 6 | <=== <=== |
4 11 |
Receive+ Receive-- |
Twisted pair no. 6 |
<=== <=== |
2 9 |
Transmit+ Transmit-- |
Twisted pair no. 1 | <=== <=== |
5 12 |
Indication+ Indication-- |
Twisted pair no. 1 |
<=== <=== |
3 10 |
Control+ Control-- |
Twisted pair no. 5 | <=== <=== |
6 13 |
Timing+ Timing-- |
Twisted pair no. 5 |
-- -- |
8 = Shield | Control GND |
Twisted pair no. 4 | -- -- |
8 = Schirm | Control GND | Twisted pair no. 4 |
===> ===> |
6 13 |
Timing+ Timing-- |
In der Regel hat die CSU/DSU
(bei uns der X.21/G.703 Konverter oder unser FME Multiplexer) das weibliche Gegenstück und ist somit das DCE Ende. Von hier kommt immer das Timing Signal zum Cisco Interface.